Transformer Rectifier Set

Transformer Rectifier Set

RDSO / Spec No. IRS: S: 91/2014
Application Indian Railways (S&T Sector) - Railway Signalling Power Supply Installations

Product Specifications & Details

The Transformer Rectifier Set manufactured by General Auto Electric Corporation (GAEC) is engineered for heavy-duty DC power requirements across Indian Railways signalling networks. Fully compliant and approved under RDSO Specification No. IRS: S: 91/2014 (Lucknow), this unit integrates a full-wave bridge rectifier with a low-ripple filter circuit (`< 5% RMS`). Featuring off-load input/output voltage selection, digital metering, HRC fuse protection, and customizable rating options, it ensures consistent, highly reliable DC output in rugged railroad environments.

Key System Features

  • Full Wave Bridge Rectifier: Integrated with advanced filter circuit for smooth DC output.
  • Low Ripple Output: Maintains low ripple content (`< 5% RMS`) for sensitive signalling circuits.
  • Flexible Tappings: Off-load input and output voltage selection switches.
  • Digital Metering: Integrated digital voltage and current display meters.
  • Dual Protection: HRC fuses placed at both input and output terminals.
  • RDSO Approved & Customizable: Fully certified under RDSO Lucknow; user specifications can be accommodated.

Technical Specifications Table

Parameter Specification Standard
Nominal Input Voltage & Freq 230V AC [110V AC Option] | 50 Hz ± 2%
OFF Load Taps 200, 210, 220 V ±1.5% [90, 95, 100 V]
Nominal Output Voltage 12V, 24V, 60V, 110V DC (or as specified by customer)
Output Voltage Settings Suitable tapping on Transformer (15V, 28V, 65V, 130V respectively)
Rated Output Current Nominally 5A, 10A, 15A, 20A, 30A, 40A, 50A, 60A, 80A
Output Ripple & No Load Current < 5% RMS Ripple | No Load Current < 10% of Max Rated Input Current
Unit Regulation <30% for 4 to 12V | <20% for 15V to 35V | <10% for 60 to 130V
Efficiency & Temp Rise > 55% (< 500VA) / > 65% (> 500VA) | Temp Rise < 55°C above ambient
Insulation & Dielectric Strength 2 kV RMS for 1 min | Insulation Resistance > 10 MΩ | Class “B” Insulation

Ordering Code Format: TR.AAABB.CC

Structure your ordering code using: TR.[Output Voltage][Current Rating].[Input Code]

  • AAA (Nominal Output): 024 for 24V DC | 110 for 110V DC
  • BB (Current Rating): 05 for 5Amp | 40 for 40Amp
  • CC (Nominal Input): 01 for 110V Input | Leave blank for standard 230V Input
  • Example: TR.02420 (230V AC to 24V DC, 20A) | TR.02420.01 (110V AC to 24V DC, 20A)

Related Products

More equipment from Power Equipment

View All In Category →
Automatic Float Cum Boost Battery Charger
IRS:S:86/2000

Automatic Float Cum Boost Battery Charger

The Automatic Float Cum Boost Battery Charger manufactured by General Auto Electric Corporation (GAEC) is engineered specifically for severe environments across the Indian Railways network. Built in compliance with RDSO Specification No. IRS:S:86/2000, it maintains power for critical Railway Signaling and Telecom installations—including Relays, Point Machines, Data Loggers, Axle Counters, and Control Circuits. The unit […]
B Type Choke For D. C. Track Circuit in Railway Signalling
IRS/S/65/83

B Type Choke For D. C. Track Circuit in Railway Signalling

The B Type Choke manufactured by General Auto Electric Corporation (GAEC) is specifically engineered for DC Track Circuits used in Railway Signalling. Designed in strict compliance with RDSO Specification No. IRS/S/65/83, this unit serves as a vital protective device for DC track circuits operating on 25 KV, 50 Hz AC electrified train routes. It provides […]
Fuse Auto Changeover System
RDSO/SPN/209/2012 Rev 1.0

Fuse Auto Changeover System

The B Type Choke manufactured by General Auto Electric Corporation (GAEC) is specifically engineered for DC Track Circuits used in Railway Signalling. Designed in strict compliance with RDSO Specification No. IRS/S/65/83, this unit serves as a vital protective device for DC track circuits operating on 25 KV, 50 Hz AC electrified train routes. It provides […]