Dry Type Distribution Transformer 9 kVA For LHB Type Non AC EOG Coaches

Dry Type Distribution Transformer 9 kVA For LHB Type Non AC EOG Coaches

RDSO / Spec No. RDSO/PE/SPEC/AC/0158-2010 Rev.0
Application Indian Railways (Rolling Stock) - LHB Non AC EOG Coaches

Product Specifications & Details

The Dry Type Distribution Transformer 9 kVA manufactured by General Auto Electric Corporation (GAEC) is designed for train lighting loads in LHB Type Non-AC End-on-Generation (EOG) coaches[cite: 14]. Approved by the Rail Coach Factory, Kapurthala, and compliant with RDSO Specification No. RDSO/PE/SPEC/AC/0158-2010 Rev.0, this air-cooled transformer operates reliably under rugged service conditions at speeds up to 200 kmph[cite: 14]. It features an under-slung IP-67 stainless steel enclosure with anti-vibration mounting pads and Class H insulation for long operational life[cite: 14].

Key System Features

  • High-Speed Rugged Design: Built for tough rail conditions at speeds up to 200 kmph in diverse climates[cite: 14].
  • Under-Slung Mounting: Anti-vibration mounting pads ensure structural durability beneath the coach frame[cite: 14].
  • Premium Insulation: Class H winding wires/strips compliant with IS: 13730 pt. 13[cite: 14].
  • Weatherproof Enclosure: Rust-free SS-304 housing providing IP-67 ingress protection[cite: 14].
  • Standard Safety Compliance: Clearance and creepage distances adhere to IS: 13947-1993 (Pollution Degree 3)[cite: 14].
  • Railway Approved: Certified by Rail Coach Factory (RCF), Kapurthala[cite: 14].

Technical Specifications Table

Parameter Specification Standard
Rating 9 kVA
Nominal Input Voltage 3 Phase, 3 wire, 750 V ±5% (line to line), 50Hz ± 3%, THD 10%
Nominal Output Voltage 3 Phase, 4 wire, 415 V ±5% (line to line), 50Hz ± 3%, 6.5KVA
3 Phase, 4 wire, 190 V ±5% (line to line), 50Hz ± 3%, 2.5KVA
Nominal Output Current 9.00 A for 6.5 KVA winding at 415 V | 7.60 A for 2.5 KVA winding at 190 V
Class of Insulation & Temp Rise Class H | Temperature Rise: < 115°C
Efficiency & % Impedance > 96% (half load to full load) | Impedance: 4% (max)
Vector Configuration & Noise Level Star-Star-Star (Yyy) | Noise Level: < 60dB at 1.0 m distance
Insulation Level & Short Circuit > 1000 MΩ | Complied As per IS 2026
Withstand Voltage Capacity High Voltage: 5 kV AC (RMS) for 1 Min | Induced Over Voltage: 830V at 100Hz for 1 Min
Total Weight & Ingress Protection 205 kg | IP-67 Protection

Related Products

More equipment from Rolling Stock Equipment

View All In Category →
Sensorless BLDC Fan for Railway Carriage (400mm sweep)
TL/0021-2005 (Rev3)

Sensorless BLDC Fan for Railway Carriage (400mm sweep)

The Sensorless BLDC Fan for Railway Carriage (400mm sweep) manufactured by General Auto Electric Corporation (GAEC) provides energy-efficient air circulation across passenger coaches[cite: 15]. Compliant with RDSO Specification No. TL/0021-2005 (Rev3), this fan features a microcontroller-based driver for precise speed control, maintaining constant fan speed across wide input voltage variations (90 to 140V DC)[cite: 15]. […]
4.5 kW Electronic Rectifier Cum Regulating Unit (ERRU)
RDSO/PE/SPEC/AC/0013-2011 Rev.3

4.5 kW Electronic Rectifier Cum Regulating Unit (ERRU)

The 4.5 kW Electronic Rectifier Cum Regulating Unit (ERRU) manufactured by General Auto Electric Corporation (GAEC) is an under-slung power management system designed to supply DC power to railway coaches while simultaneously regulating alternator output to charge battery banks. Compliant with RDSO Specification No. RDSO/PE/SPEC/AC/0013-2011 Rev.3, this unit features microprocessor-based IGBT control for smooth operational […]
LED Based Emergency Light Unit
RDSO/PE/SPEC/AC/0180-2016 (Rev0)

LED Based Emergency Light Unit

The LED Based Emergency Light Unit manufactured by General Auto Electric Corporation (GAEC) is a safety illumination system designed for railway rolling stock. Built in accordance with RDSO Specification No. RDSO/PE/SPEC/AC/0180-2016 (Rev0), this unit automatically provides up to 12 hours of uninterrupted coach illumination during main coach input power failures or low battery conditions. Equipped […]